Digital X-ray Radiography Machine with Portable Flat Panel Detector for Advanced DR Imaging
SKU: UMY-XM-023
Brand: Umy
MOQ: 1
Origin: China
Quick Info.
- SKU NO.: UMY-XM-023
- Device Classification: Class Ⅱ
- Warranty: 1 Year
- Power Source: Electric
- Transport Package: Carton or Wooden Cases
- Origin: China
- Material: Aluminum and magnesium alloys
- After-Sale Service: Online Technical Support
- Production Capacity: 500 Sets/Year
The digital X-ray radiography machine with a portable flat panel detector offers high-resolution imaging for a variety of diagnostic needs. This advanced DR (Digital Radiography) system ensures fast, accurate image acquisition, improving workflow efficiency in busy medical environments. The portable flat panel detector allows for flexible use, making it ideal for mobile setups or clinics where space is limited. With reduced radiation exposure and enhanced image quality, this machine provides reliable diagnostics for superior patient care.
The Specific Parameters
ITEMS | PARAMETERS |
---|---|
Flat Panel Detector | |
Type | TFT monolithic amorphous silicon |
Panel Size | 430mm × 430mm |
Efficient Imaging Size | 17 × 17 inch |
Acquisition Pixel Matrix | ≥3072 × 3072 |
Pixel Pitch | ≤146µm (≤120µm or ≤100µm available for an extra cost of USD 3427) |
Spatial Resolution | 3.7LP/MM |
Pixel Gray Scale | 16 Bit |
Image Acquisition and Transmission Time | 3s |
High Frequency and High Voltage Generator | |
Max Output Power | 50kW |
Input Power Supply | 380VAC, Three Phase |
Output Voltage | 40~150kV |
Tube Current Range | 10~800mA |
Exposure Time Range | 1ms – 10,000ms |
mAs Range | 0.1mAs ~ 1000mAs |
Support | AEC, APR automatic exposure |
Features | Diagnostic self-test and display |
X-Ray Bulb Tube Assembly | |
Focus | 0.6mm / 1.5mm |
Nominal Electric Power | 21kVA / 52kVA |
Maximum Voltage | 150kV |
Anode Target Angle | 12° |
Bed for Radiography | |
Longitudinal Movement Range | ±130mm |
Lateral Movement Range | ±280mm |
Vertical Chest X-Ray Stand | |
Vertical Movement Range | 1400 ± 20mm |
Radiography Stand | |
Rotation Range of Tube Assembly | ≥ ±90°; Positioning for each 90° |
Longitudinal Movement Range | 1640 ± 20mm |
Vertical Movement Range | 1180 ± 20mm |
AEC (Optional) | |
Detection Number of Outliers | 3 |
Tube Voltage Range | 40-150kV |
Light Time Range | 1ms – 10s |
The Grid and Beam Limiting Device | |
Grid Material | Aluminum based grid |
Size | 18 × 18 inch (48 × 48cm) |
Grid Ratio | 0.41736111111111 |
Density | 215C |
Grid Focal Length | 1000mm |