300W High-Frequency Electrosurgical Generator with Precision Fabrication
This 300W high-frequency electrosurgical generator is expertly fabricated for precision and efficiency in surgical applications. Designed for versatile use, it provides superior cutting and coagulation capabilities with minimal tissue damage. Ideal for general, plastic, and laparoscopic surgeries, this device ensures safety and reliability in clinical settings. Its robust construction and advanced technology make it a dependable solution for hospitals and surgical centers worldwide.
Quick Info.
Maximum output power: 300W
Safety standard: I-type BF-type
Ambient temperature range: +10℃~ +40℃
Relative humidity range: 30 ~ 75%
Atmospheric pressure: 700~ 1060 hPa
Power supply: 220V ± 22V 50Hz ± 1Hz
Operating frequency: 530KHz±2
Overall energy consumption: ≤1400VA
- SKU NO.: UMY-SE-054
- Warranty: 1 Year
- Origin: China
The Specific Parameters
– Maximum output power: 300W
– Five output modes: (1) pure cut, (2) mixed cut 1, (3) mixed cut 2, (4) electrocoagulation, (5) bipolar condensate;
– Electric cut mode: pure cut 100% cut, mixed cut 1 70 % cut, 30% coagulation; mixed cut 2 50 % cut, 50% coagulation;
– Pure cut: Maximum output power 300W, enabling easy surgery on any tissues and structures;
– Mixed cut: Applicable for any tissue, good coagulation effect when conducting cutting;
– Electrocoagulation: Applicable for general open surgery and fine surgical point coagulation, featuring deep tissue coagulation layer and excellent coagulation effect;
– Bipolar coagulation: When the tissues achieve the effect of coagulation, the output power will begin to reduce slowly to achieve good coagulation effect;
– Panel operation: Overall microcomputer automatic control, two-zone (LED) digital display, key function/power, switch/settings, waterproof panel design
– Automatic adjustment: Automatically fine adjust power in a certain range to ensure the consistency of the cutting effect;
– Automatic recognition: Neutral unipolar/bipolar plate automatic recognition, when using the dual-circuit plates and the contact area less than 60%, it should automatically stop the power output and send sound-light alarm until the contact area returns to normal, which could effectively avoid burning patients by plates.
Safety standard | I-type BF-type | |
Ambient temperature range | +10℃~ +40℃ | |
Relative humidity range | 30 ~ 75% | |
Atmospheric pressure | 700~ 1060 hPa | |
Power supply | 220V ± 22V 50Hz ± 1Hz | |
Operating frequency | 530KHz±2 | Load: Monopolar cut coagulation 300Ω, Bipolar coagulation 100Ω |
Rated output power | a)Pure cut: 1W ~ 300W(Peak voltage 1500V) | b)Mixed cut 1: 1W ~ 250W(Peak voltage 2000V) |
c)Mixed cut 2: 1W ~ 150W(Peak voltage 2500V) | d)Electrocoagulation 1: 1W~ 100W(Peak voltage 3500V) | |
e)Bipolar coagulation:1W ~ 50W(Peak voltage 620V) | ||
Overall energy consumption | ≤1400VA | |
Transport and storage | a)Ambient temperature range: -40℃~ +55℃ | b) Relative humidity range: ≤93% |
c)Atmospheric pressure range: 500hPa ~1060hPa |